Power Amplifier software

Software repository

Bugs:

when disconnecting antenna, emergency shutdown then tries to go back at full-7 with alert 8; does not shut down from this alert and keep looping exposing amplifier to reflection

when detecting power too large, kicks in -7 dB but keeps at that level without attempting to reset power to large value if error is cleared on input power

as Jim suggested, 47 dBm is too tight for the safety trip. Recommend 48.5 dBm, we have plenty of cooling.


  • TOMCO can be in 5 tomco_mode
	t_mode	          mode btm_pow	standby	ptt	rf_in_on	remarks
   0  MODE_NONE
	1	MODE_PWR_OFF  		0	  any	    any	   any  	off
	2	MODE_STANDBY		1	   0	    any  	any	power-saving
	3	MODE_NOPTT		   1	   1	     1	   any	dissipates
	4	MODE_IDLEXMIT		1	   1	     0	    0	   dissipates
	4	MODE_IDLEXMIT	   1	   1	     0	    1		full power

	allowed orderly transitions
				  	-> NOPTT <-
		OFF 	<-> STANDBY  <-|	   |-> TRANSMIT
					-> IDLE  <-

	forbidden transition without precise control of standby, ptt and rf_in_on

		OFF 	<-> TRANSMIT
  • RABBIT can operate in 5 rabbit_mode:
	0 boot mode
	1 normal loop mode, transmit off, standby
	2 normal loop mode, transmit on
	3 error loop mode, trying to recover, otherwise switch to mode 4
	4 cli mode