PA 1-17
Updated 12/04/2017 Test Frequency : 27.5 MHz
TOMCO serial number 18486 0.5-150 MHz (removed)
WERLATONE serial number 109531 1-50 MHz
FILTER none

Settings

  • AUTO DHCP - ok
  • FRONT LED - ok; when no load, LED OFF - ok
  • default db in = 2dBm

Power Supply Measurements

AC voltage setting: 115V
DC voltage (V): 26.5
Ammeter reading (A):
UPS power load w/ 2dBm input(W):

Signal Measurements

  • RF power meter: Mini Circuits PWR-SEN-6GHS USB power sensor
  • internal attenuator set at 0 dBm
  • power meter 50 dBm offset applied for measurements at rear panel connectors
  • 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
LocationMeter Reading (dBm)Rabbit Reading (dBm)Comments
IN connector+2.001.6 
FWD connector-------- 
RFL connector-------- 
OUT connector+46.3447.5stable @ 0dB

Temperature Measurements

  • temperature meter: DM6802B Digital Thermometer
LocationMeter Reading (deg C)Rabbit Reading (deg C)Comments 
BTC41.640.0 
MCI24.621.8 
AMB26.025.5 

Spectrum Analyzer Images

Input Signal

At FWD connector

At RFL connector

At OUT connector