PA 1-15
Updated 04/04/2016
Test Frequency : 26.5 MHz
TOMCO serial number 18489 0.5-150 MHz
WERLATONE serial number 109532 1-50 MHz
FILTER 26 MHz (*doug williams)
Settings
- AUTO DHCP - ok
- FRONT LED - ok; when no load, LED OFF - ok
- default db in = 1dBm
Power Supply Measurements
AC voltage setting: 115V
DC voltage (V): 26.5
Ammeter reading (A): 2.0
UPS power load w/ 2dBm input(W):
Signal Measurements
- RF power meter: Mini Circuits PWR-SEN-6GHS USB power sensor
- internal attenuator set at 0 dBm
- power meter 50 dBm offset applied for measurements at rear panel connectors
- 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
Location | Meter Reading (dBm) | Rabbit Reading (dBm) | Comments | |
IN connector | +2.05 | 1.9 | |
FWD connector | ---- | ---- | |
RFL connector | ---- | ---- | |
OUT connector | +47.02 | 47.1 | stable @ 1dB |
| +47.57 | 47.5 | stable @ 0dB, 41.5 C |
Temperature Measurements
- temperature meter: DM6802B Digital Thermometer
Location | Meter Reading (deg C) | Rabbit Reading (deg C) | Comments | |
BTC | 42.2 | 41.8 | |
MCI | 25.8 | 23.6 | |
AMB | 26.8 | 27.2 | |
Spectrum Analyzer Images
Input Signal
At FWD connector
At RFL connector
At OUT connector