Updated 04/04/2016

Test Frequency : 26.5 MHz TOMCO serial number 18489 0.5-150 MHz
WERLATONE serial number 109532 1-50 MHz
FILTER 26 MHz (*doug williams)

Settings

  • AUTO DHCP - ok
  • FRONT LED - ok; when no load, LED OFF - ok
  • default db in = 1dBm

Power Supply Measurements

AC voltage setting: 115V
DC voltage (V): 26.5
Ammeter reading (A): 2.0
UPS power load w/ 2dBm input(W):

Signal Measurements

  • RF power meter: Mini Circuits PWR-SEN-6GHS USB power sensor
  • internal attenuator set at 0 dBm
  • power meter 50 dBm offset applied for measurements at rear panel connectors
  • 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
LocationMeter Reading (dBm)Rabbit Reading (dBm)Comments
IN connector+2.051.9 
FWD connector-------- 
RFL connector-------- 
OUT connector+47.0247.1stable @ 1dB
 +47.5747.5stable @ 0dB, 41.5 C

Temperature Measurements

  • temperature meter: DM6802B Digital Thermometer
LocationMeter Reading (deg C)Rabbit Reading (deg C)Comments 
BTC42.241.8 
MCI25.823.6 
AMB26.827.2 