Notes
- TOMCO serial number 5369
- Unit configured for 16 MHz
Power Supply Measurements
AC voltage setting: 115 V
DC voltage (V): 23 .9 V
Ammeter reading (A): 1.5 A at 2.01 dBm in
UPS power load w/ 2dBm input(W):
Signal Measurements
- RF power meter: Mini Circuits PWR-SEN-6G+ USB power sensor
- internal attenuator set at 0 dBm
- power meter 50 dBm offset applied for measurements at rear panel connectors
- 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
Location | Meter Reading (dBm) g | Rabbit Reading (dBm) | Comments | |
IN connector | 2.01 | 1.4 | |
FWD connector | 46.73 | 46.7 | |
RFL connector | 13.23 | 12.7 | |
OUT connector | 46.72 | 46.7 | |
Temperature Measurements
- temperature meter: DM6802B Digital Thermometer
Location | Meter Reading (deg C) | Rabbit Reading (deg C) | Comments | |
BTC | 28.4 | 27.8 | |
MCI | 24.6 | 24.6 | |
AMB | | 23.9 | |
2013/11/22 found non-working
Diagnostic:
- intermittent 10 dB attenuator -> replaced
- outputs only 24 dBm at 2 dBm input.
- rigged TOMCO directly with 0 dBm input -> 46.4 dBm output on MCI meter+100W load; OK
- same input, connect ouput through filter+Werlatone+internal MIC+100 W load -> says 25.0 dBm; wrong!
- connect input through internal attenuator and input box ->