PA 1-09
Updated 03/21/2016
Test Frequency : 8.25 MHz
TOMCO serial number 6162 wrong serial 0.1-30 MHz
WERLATONE serial number 96391 1-30 MHz
FILTER (9MHz) serial number 0001 (*doug williams)
Settings
- AUTO DHCP - ok
- FRONT LED - ok; when no load, LED OFF - ok
- default dB in = 1 dBm
Power Supply Measurements
AC voltage setting: 115 V
DC voltage (V): 26.5
Ammeter reading (A): 1.7 Amps
UPS power load w/ 2dBm input(W): Not Available
Signal Measurements
- RF power meter: Mini Circuits PWR-SEN-6GHS USB power sensor
- internal attenuator set at 0 dBm
- power meter 50 dBm offset applied for measurements at rear panel connectors
- 10 dB attenuators used at FWD and RFL outputs to achieve 50 dB atten of actual signal
Location | Meter Reading (dBm) | Rabbit Reading (dBm) | Comments | |
IN connector | 1.86 | 1.5 | |
FWD connector | --- | --- | |
RFL connector | --- | --- | |
OUT connector | 47.19 | 46.8 | |
Temperature Measurements
- temperature meter: DM6802B Digital Thermometer
Location | Meter Reading (deg C) | Rabbit Reading (deg C) | Comments | |
BTC | 29.2 | 33.8 | Meter Reading TOMCO CASE |
MCI | 22.7 | 18.5 | Meter Reading on Power Sensor3 |
AMB | 23.2 | 25.9 | Meter reading on back compartment |
(old notes)
Spectrum Analyzer Images
Input Signal
At FWD connector
At RFL connector
At OUT connector