PA 1-02 (Updated 03/21/2016)

Test Frequency : 8.25 MHz TOMCO serial number 6162 0.1-30 MHz
WERLATONE serial number 96390 1-30 MHz
FILTER serial number 0003 (*doug williams)

Settings

  • AUTO DHCP - ok
  • FRONT LED - ok; when no load, LED OFF - ok
  • default db in = 2dBm

Power Supply Measurements

AC voltage setting: 115 V
DC voltage (V): 26.5
Ammeter reading: 1.6 A
UPS power load w/ 2dBm input(W): not available

Signal Measurements

  • RF power meter: Mini Circuits PWR-SEN-6HS+ USB power sensor
  • internal attenuator set at 0 dBm
  • power meter 50 dBm offset applied for measurements at Tomco output and rear panel connectors
LocationMeter Reading (dBm)Rabbit Reading (dBm)Comments
IN connector+1.86+1.4 
OUT connector+47.45+47.6not stable (5db down on output)
 +46.3+46.3@ 2db internal attenuator
RFL connector-------- 
FWD connector------different RF load used

Temperature Measurements

  • temperature meter: DM6802B Digital Thermometer
LocationMeter Reading (deg C)Rabbit Reading (deg C)Comments 
BTC33.235.6 
MCI22.821.2 
AMB26.627.4 

(old notes) Notes

  • second bench test 12/27/2012 after deployment at Kok
  • unit configured for 16 MHz

Spectrum Analyzer Images

Input Signal

At FWD connector

At RFL connector

At OUT connector

  • not available at this time

Bench Photos 2012-12-27